The structure of the automatic air circuit breaker

( 1) Mechanism of the automatic air circuit breaker by transmission mechanism and the free trip mechanism of two parts. When switching through the drive mechanism on the trip free agency will switch. And free trip mechanism associated with contact system and protection system, through its role to make contact on or off. ( 2) Contact automatic switch contact usually adopts the block, the contact part of the silver piece to reduce the contact resistance. Generally rated current is larger than 600 a automatic switch should be installed arcing contact, in order to protect the main contact from arc burn out. ( 3) Arcing device of the automatic air circuit breaker arcing device usually adopt grid arc extinguish chamber, because the grating grooves with different shapes, thus improve the arcing ability. Arcing chamber with asbestos board or clay, can prevent the interphase short circuit caused by arcing. ( 4) Tripping device (1) loss of pressure trip, except for tripping actuator, and under-voltage protection. (2) the overcurrent trip, for overload and short circuit protection. Overcurrent tripping device has two kinds of double metal plate and electromagnetic. Thermal trip trip for flow, its effect is overload, the current make the bimetallic strip right end bending down, after a period of time, in the spring, the switch trip, to cut off the main circuit. Electromagnetic tripping device is used, short circuit, short circuit current through the coil of electromagnetic trip, produce strong magnetic field, pull-up armature, switch trip. DZ10 series automatic air circuit breaker thermal trip, its rated current has 15, 20, 30, 40, 50, 60, 80, 100 & middot; · · · · · · · · · 600 a, etc. , according to the working current of the circuit choose proper thermal trip. Rated current of the electromagnetic trip for 15, 20, 25, 30, 40, 50, 100, 250, 400, 600 a, etc. , its current action within 3 ~ 10 times rated current regulation.

GET IN TOUCH WITH Us
recommended articles
knowledge News
A transmission device KTTA diesel engine accessories, attachment of the power from the crankshaft.
The activation method for automatic diesel generator has two kinds, one kind is using artificial way of manual start, another kind is started automatically by the diesel generator control module.
With the development of international economy, in order to achieve the integration of the domestic economy, domestic industries are in rapid development, in recent years, diesel generating sets industry has made rapid development in our country.
Maintenance of diesel generator set of points to note: 1, when some users in the diesel filter care, even put it away.
The studio a cycle of a diesel generator set, so while she was working in a continuous cycle need a unit to describe the number of indicators to do work.
Six cylinder in-line diesel engine start-up circuit.
1 the CAM follower CAM assembly as shown in figure 3 - from the east side assembly
17.
CAM follower and the push rod assembly method and steps are as follows: the CAM follower arm and push rod assembly method and steps are as follows: 1)

The CAM follower arm cover gasket loaded on the cylinder block, the thickness of gasket used should be the same as the remove the gasket thickness.
Abroad in recent 10 years, based on modern control theory in the multivariate linear optimal controller development aspect, has achieved rapid development.
no data

+86-13696836615

Jet Power Generator has experienced rapid growth and currently a leading power equipment diesel generator manufacturer in China.

Contact Us

Sale Tel: +86-591-83211428
Sale Tel: +86-13696836615 (Whatsapp/Wechat)
Sale Fax: +86-591-83211428
E-mail: info@jet-power.cn
Office Address: A1-1408, Wanda Piazza, Taijiang District, Fuzhou, China
Factory Address: Industrial park,Tiehu, Fuan City, Fujian, China
Copyright © 2025 Jet Power Generator | Sitemap
Customer service
detect